The Perfect Combo: Amazing Speed & Massive Data
Explore Salus' series of cutting-edge next-generation sequencing (NGS) platforms.
By leveraging the sequencing-by-synthesis (SBS) principles, Salus Sequencing Platforms integrate proprietary technical advancements including larger optical systems, rapid biochemistry, and high-density chip design. These cutting-edge instruments are engineered to meet the diverse sequencing needs across industry and academic fields, empowering scientists to explore the secret of genomes and unlock new possibilities in life science.

| Sequencing Reagent Set | Read Length | Data Output | Time | Q30 |
|---|---|---|---|---|
| 25M | SE400 | 10.0 Gb | 18 hr | ≥ 80% |
|
PE300 |
15.0 Gb | 25 hr |
≥ 80% |
|
| SE50 | 1.25 Gb | 3.4 hr |
≥ 90% |
|
|
SE75 |
1.875 Gb | 4.1 hr |
≥ 90% |
|
|
SE100 |
2.5 Gb | 4.7 hr |
≥ 90% |
|
| PE150 | 7.5 Gb | 10.9 hr | ≥ 90% | |
| 60M | SE50 | 3.0 Gb | 3.7 hr | ≥ 90% |
| SE75 | 4.5 Gb | 4.5 hr | ≥ 90% | |
| SE100 | 6.0 Gb | 5.4 hr | ≥ 90% | |
| PE150 | 18.0 Gb | 12 hr | ≥ 90% | |
| 100M | SE50 | 5.0 Gb | 3.8 hr | ≥ 90% |
| SE75 | 7.5 Gb | 4.6 hr | ≥ 90% | |
| SE100 | 10.0 Gb | 5.5 *hr | ≥ 90% | |
|
PE150 |
30.0 Gb |
13.2 hr |
≥ 90% |
|
| SE400 | 40.0 Gb | 20.5 hr | ≥ 80% |
*The sequencing time is for dual index (8+8);
*Sequencing time and data quality may fluctuate due to the different libraries used
| Methods | Applications | Data volume / sample | Read Length |
25M Samples / run |
60M Samples / run |
100M Samples / run |
|---|---|---|---|---|---|---|
| Low-pass Whole Genome Sequencing | NIPT | ~5M reads | SE50 | 5 |
12 |
20 |
|
Targeted Sequencing (Capture / Multiplex Amplification) |
Targeted Pathogen Sequencing (tNGS) | 0.5M ~ 1M reads | SE50 | 25 / 50 |
60 / 120 |
100 / 200 |
| Small Panel for Tumor Companion diagnostics | ~1 Gb | PE150 | 7 | 18 | 30 | |
| Small Panel for Genetic diseases (Deafness, Metabolism) | 3 ~ 5 Gb | PE150 | 1 ~ 2 | 3 ~ 6 | 6 ~ 10 | |
| 16S Sequencing | ~0.5M reads | PE300 | 50 | / | / | |
| Forensic DNA Identification | ~0.5M reads | SE400 | 50 | / | 200 | |
|
Small Genome Sequencing (Tuberculosis, Influenza, etc.) |
Bacterial / Virus | ~1 Gb | PE150 | 7 | 18 | 30 |
| Methylation Sequencing | Pan-cancer early screening | ~4 Gb | PE150 | 2 | 4 | 7 |
| Products | Product Code |
|---|---|
|
Saluseq Nimbo Sequencing Reagent Set(SRL-SE50-25M) |
SL-S00902 |
|
Saluseq Nimbo Sequencing Reagent Set(PRL-PE150-25M) |
SL-S00915 |
|
Saluseq Nimbo Sequencing Reagent Set(SRL-SE50-60M) |
SL-S00917 |
|
Saluseq Nimbo Sequencing Reagent Set(PRL-PE150-60M) |
SL-S00929 |
|
Saluseq Nimbo Sequencing Reagent Set(SRL-SE50-100M) |
SL-S01543 |
|
Saluseq Nimbo Sequencing Reagent Set(PRL-PE150-100M) |
SL-S01547 |
| *For more proeuct information and specifications please contact us | |
| Parameter | Specifications | |
|---|---|---|
| Size | 619 mm(W) x 682 mm(D) x738 mm(H) | |
| Weight | 115 Kg | |
| Power Requirements | Input Voltage | 100V - 240V~ |
| Frequency | 50 / 60 Hz | |
| Powe | 1000 VA | |
| Fuse | T10AH250V | |
| Instrument Configuration | Display | 13.3 inch |
| Resolution | 1920 x1080 | |
| Operating Environment | Temperature | 19°C - 25°C |
| Humidity | 20%RH ~ 80%RH (No Condensation) | |
| Altitude | ≤ 2000m | |
| Instrument Control Computer | CPU | 12th Gen Intel(R) core(TM) i9-12900 |
| Memory | 128GB | |
| Storage | 2TB SSD | |
| OS | Windows 10 X64 | |
The Perfect Combo: Amazing Speed & Massive Data
A multi-purpose benchtop Salus Pro sequencer, providing high quality data with speed, compatibility and affordability.
Spatial Transcriptomics (ST) Chip for mRNA capture and spatial localization at 1.4 μm resolution
Strike Fast & Hit the Target
| Sequencing Reagent Set | 80M | 150M | 250M | 500M | 1000M* | Q30** |
|---|---|---|---|---|---|---|
| SE50 | 4.0 Gb / 4.8 hr | 7.5 Gb / 6 hr | 12.5 Gb / 6.6 hr | 25.0 Gb / 9 hr | / | ≥90% |
| SE75 | 6.0 Gb / 6 hr | 11.2 Gb /7 hr | 18.7 Gb / 7.7 hr | 37.5Gb / 12 hr |
/ |
≥90% |
| SE100 | 8.0 Gb / 7.2 hr | 15.0 Gb / 8 hr | 25.0 Gb/ 9.2 hr | 50.0 Gb / 16 hr |
/ |
≥90% |
| PE75 | / | / | / | 75.0 Gb / 23 hr | 150 Gb / 26 hr | ≥85% |
| PE100 | / | / | / | 100.0 Gb / 30 hr | 200 Gb / 33 hr | ≥85% |
| PE150 | 24.0 Gb / 20 hr | 45.0 Gb / 24 hr | 75.0 Gb/ 25 hr | 150.0 Gb / 42 hr | 300 Gb / 45 hr | ≥85% |
| Sequencing Methods |
Key Applications |
Data Volume Per Sample |
Read Length |
80 M Samples / Run |
150 M Samples / Run |
250 M Samples / Run |
500 M Samples / Run |
1000 M Samples / Run |
|---|---|---|---|---|---|---|---|---|
|
Low-pass Whole Genome Sequencing |
NIPT | 5 M reads | SE 50 | 16 / 32 | 30 / 60 | 50 / 100 | 100 / 200 | - |
| CNV-seq / PGT-A | 5 M reads | SE 75 | 16 / 32 | 30 / 60 | 50 / 100 | 100 / 200 | - | |
|
Small Whole Genome Sequencing |
Shotgun Metagenomics | 20 M reads | SE 75 | 4 / 8 | 8 / 16 | 12 / 25 | 25 / 50 | - |
| Microbe, Virus WGS | 1 Gb | PE 150 | 24 / 48 | 45 / 90 | 75 / 150 | 150 / 300 | 300 / 600 | |
|
Targeted Sequencing (Target Enrichment / Amplicon Sequencing) |
Pathogen Targeted NGS (tNGS) | 1 M reads | SE 50 | 80 / 160 | 150 / 300 | 250 / 500 | 500 / 1000 | - |
| Small Panel Sequencing | 1 Gb | PE 150 | 24 / 48 | 45 / 90 | 75 / 150 | 150 / 300 | 300 / 600 | |
| Large Panel Sequencing | 10 Gb | PE 150 | 3 / 6 | 5 / 10 | 7 / 15 | 15 / 30 | 30 / 60 | |
| WES | 12 Gb | PE 150 | 2 / 4 | 3 / 7 | 6 / 12 | 12 / 25 | 25 / 50 | |
| Methylation Sequencing | Multi-cancer Early Detection | 4 Gb | PE 150 | 6 / 12 | 11 / 22 | 18 / 36 | 36 / 75 | 72 / 150 |
| RNA Sequencing | Bulk RNA-seq | 6 Gb | PE 100 | - | - | - | 16 / 32 | 32 / 64 |
| Single Cell RNA Sequencing |
20 - 50k reads/cell (Capture 10000 cells) |
PE 50 + 100 | - | - | - | 1 / 5 | 2 / 10 | |
| Whole Genome Sequencing |
Human Whole Genome Sequencing (30X) |
100 Gb | PE 150 | - | - | - | 1 / 2 | 3 / 6 |
| Products | Product Code |
|---|---|
| Salus Pro Sequencer | SL-Y00125 |
| Salus Pro Sequencing Reagent Set (SRM-SE50-80M) | SL-S00238 |
| Salus Pro Sequencing Reagent Set (SRM-SE75-80M) | SL-S00239 |
| Salus Pro Sequencing Reagent Set (PRM-PE75-150M) | SL-S00247 |
| Salus Pro Sequencing Reagent Set (PRM-PE150-500M) | SL-S00205 |
| Salus Pro Sequencing Reagent Set (PRM-PE150-1000M) | SL-S01510 |
|
*For more proeuct information and specifications please contact us |
|
| Parameter | Specifications | |
|---|---|---|
| Size | 1265mm(W) x 700mm(D) x 675mm(H) | |
| Weight | 210 Kg | |
| Power | Input Voltage | 100V - 240V~ |
| Frequency | 50 / 60Hz | |
| Power | 1200VA | |
| Fuse | T15AH250V | |
| Instrument Configuration | Type | Capacitive |
| Display | 21.5 inch | |
| Resolution | 1920x1080 | |
| Operating Environment | Temperature | 19℃-25℃ |
| Humidity | 20%RH-80%RH (No Condensation) | |
| Altitude | ≤2000m | |
| Instrument Control Computer | CPU | Intel Xeon® Silver 4216 |
| Storage | 32 GB DDR4+4 | |
| Memory | 10 TB HDD*4; 512 GB+2048 GB SSD | |
| OS | Windows 10 x64 | |
| Maximum sound pressure | 75 dB(A) | |
The Perfect Combo: Amazing Speed & Massive Data
A multi-purpose benchtop Salus Pro sequencer, providing high quality data with speed, compatibility and affordability.
Spatial Transcriptomics (ST) Chip for mRNA capture and spatial localization at 1.4 μm resolution
Strike Fast & Hit the Target

| Sequencing Reagent Set | Lanes | Read Length | 1 x Data / Run | 2 x Data / Run | Time | Q30 |
|---|---|---|---|---|---|---|
| 1500 M | 4 | SE 75 | 112.5Gb | 225 Gb | 9.5 hr | ≥ 90% |
| PE 100 | 300 Gb | 600 Gb | 15 hr | ≥ 85% | ||
| PE 150 | 450 Gb | 900 Gb | 21 hr | ≥ 85% | ||
| 3000 M* | 4 | PE 100 | 600 Gb | 1200 Gb | 17 hr | ≥ 85% |
| PE 150 | 900 Gb | 1800 Gb | 24 hr | ≥ 85% |
| Application |
1 x 1500 M (Samples / Run) |
2 x 1500 M (Samples / Run) |
1 x 3000 M (Samples / Run) |
1500 M + 3000 M (Samples / Run) |
2 x 3000 M (Samples / Run) |
|---|---|---|---|---|---|
|
WES (15 Gb / Sample) |
30 | 60 | 60 | 90 | 120 |
|
Large Panel (35 Gb / Sample) |
12 | 25 | 25 | 38 | 51 |
|
WGS (100 Gb / Sample) |
4 | 9 | 9 | 13 | 18 |
|
WGBS (100 Gb / Sample) |
4 | 9 | 9 | 13 | 18 |
|
Single Cell (100 Gb / Sample) |
4 | 9 | 9 | 13 | 18 |
|
Spatial Transcriptomics (200 Gb / Sample) |
2 | 4 | 4 | 6 | 9 |
| Products | Product Code |
|---|---|
| Salus EVO Sequencing Reagent Set(SRH-SE75-1500M) | SL-S01465 |
| Salus EVO Sequencing Reagent Set(PRH-PE100-1500M) | SL-S01109 |
| Salus EVO Sequencing Reagent Set(PRH-PE150-1500M) | SL-S01113 |
| Salus EVO Sequencing Reagent Set(PPH-PE100-3000M) | SL-S01057 |
| Salus EVO Sequencing Reagent Set(PPH-PE150-3000M) | SL-S01061 |
| *For more product information and specifications please contact us | |
| Parameter | Specifications | |
|---|---|---|
| Dimensions | 870 mm(W) × 995 mm(D) × 1616 mm(H) | |
| Weight | 350 Kg | |
| Power Requirements | Input voltage | 200 V - 240 V~ |
| Frequency | 50 / 60 Hz | |
| Power | 1200 VA | |
| Fuse | T15AH250V | |
| Instrument Configuration | Type | Capacitive |
| Display | 21.5 inch | |
| Resolution | 1920 x 1080 | |
| Operating Environment | Temperature | 19°C - 25°C |
| Humidity | 20% RH - 80% RH (No Condensation) | |
| Altitude | ≤ 2000m | |
| Instrument Control Computer | CPU | 2 x AMD7643 (Single 48 core / 96 - thread 2.3 - 3.6G / 225W) |
| Memory | 1 TB GB DDR4 | |
| Storage | 11 TB HDD * 3 ; 512 GB + 3.84 TB * 2 SSD | |
| OS | Windows 10 X64 | |
| Maximum Sound Pressure | 75 dB(A) | |
The Perfect Combo: Amazing Speed & Massive Data
A multi-purpose benchtop Salus Pro sequencer, providing high quality data with speed, compatibility and affordability.
Spatial Transcriptomics (ST) Chip for mRNA capture and spatial localization at 1.4 μm resolution
Strike Fast & Hit the Target
info@salus-bio.com
+86 0755-23745832Shenzhen: 20/F, Building 1, Hengtaiyu Research Park, Shenzhen, Guangdong, P.R. China
Shanghai: 4/F, Building 6, No. 830, Chengyin Road, Baoshan District, Shanghai, P.R. China