Contact
EN
CN EN
Home - Products - Sequencing Platforms - Sequencing Platform
Explore Salus NGS Platforms
  • Reads / Run
    20 M / 25 M / 60 M
    Data Output / Run
    1.25 Gb ~ 18 Gb
    Run Time
    3.4 hr ~ 12 hr
    Applications
    Personalized diagnostics, NIPT, forensics, eDNA, targeted-NGS, etc.
    • Highlighted Features
    • Specifications
    • Applications
    • Ordering Information
    • Instrument Specifications

    Sequencing Reagent Set Read Length Data Output Time Q30
    20M SE400 8.0 Gb 20 hr ≥ 80%
    PE300 12.0 Gb 28 hr ≥ 80%
    25M SE50 1.2 Gb 3.4 hr ≥ 90%
    SE75 1.8 Gb 4.1 hr ≥ 90%
    SE100 2.5 Gb 4.7 hr ≥ 85%
    PE150 7.5 Gb 10.9 hr ≥ 85%
    60M SE50 3.0 Gb 3.8 hr ≥ 90%
    SE75 4.5 Gb 4.6 hr ≥ 90%
    SE100 6.0 Gb 5.4 hr ≥ 85%
    PE150 18.0 Gb 12 hr ≥ 85%

    *The sequencing time is for dual index (8+8);
    *The time mentioned above is the theoretical sequencing time;
    *Sequencing time and data quality may fluctuate due to the different libraries used

    Methods Applications Data volume / sample Read Length 20M
    Samples / run
    25M
    Samples / run
    60M
    Samples / run
    Low-pass Whole Genome Sequencing NIPT ~5M reads SE50 / 5 12
    Targeted Sequencing
    (Capture / Multiplex Amplification)
    Targeted Pathogen Sequencing (tNGS) 0.5M ~ 1M reads SE50 / 25 / 50 60 / 120
    Small Panel for Tumor Companion diagnostics ~1 Gb PE150 / 7 18
    Small Panel for Genetic diseases (Deafness, Metabolism) 3 ~ 5 Gb PE150 / 1 / 2 3 / 6
    16S Sequencing ~0.5M reads PE300 40 / /
    Forensic DNA Identification ~0.5M reads SE400 40 / /
    Small Genome Sequencing
    (Tuberculosis, Influenza, etc.)
    Bacterial / Virus ~1 Gb PE150 / 7 18
    Methylation Sequencing Pan-cancer early screening ~4 Gb PE150 / 2 4

    *The number of samples is estimated after careful consideration of library pooling bias and is for reference only.
    Products Product Code
    Saluseq Nimbo Sequencing Reagent Set (SRL-SE50-20M) SL-S00434
    Saluseq Nimbo Sequencing Reagent Set (SRL-SE50-25M) SL-S00326
    Saluseq Nimbo Sequencing Reagent Set (PRL-PE150-25M) SL-S00330
    Saluseg Nimbo Sequencing Reagent Set (SRL-SE75-60M) SL-S00332
    *For more proeuct information and specifications please contact us

    Parameter Specifications
    Size 619 mm(W) x 682 mm(D) x738 mm(H)
    Weight 115 Kg
    Power Requirements Input Voltage 100V - 240V~
    Frequency 50 / 60 Hz
    Powe 1000 VA
    Fuse T10AH250V
    Instrument Configuration Display 13.3 inch
    Resolution 1920 x1080
    Operating Environment Temperature 19°C - 25°C
    Humidity 20%RH ~ 80%RH (No Condensation)
    Altitude ≤ 2000m
    Instrument Control Computer CPU 12th Gen Intel(R) core(TM) i9-12900
    Memory 64GB DDR5
    Storage 2TB SSD
    OS Windows 10 X64

  • Reads / Run (Up to two chips per run)
    80 M / 150 M / 250 M / 500 M / 1000 M
    Data Output / Run
    4 Gb ~ 600 Gb
    Run Time
    4.8 hr ~ 42 hr
    Applications
    NIPT, Shotgun Metagenomics, Large Panel Sequencing, WES, etc.
    • Highlighted Features
    • Specifications
    • Applications
    • Ordering Information
    • Instrument Specifications

    Sequencing Reagent Set 80M 150M 250M 500M 1000M*
    SE50 4.0 Gb / 4.8 hr 7.5 Gb / 6 hr 12.5 Gb / 6.6 hr 25.0 Gb / 9 hr /
    SE75 6.0 Gb / 6 hr 11.2 Gb /7 hr 18.7 Gb / 7.7 hr 37.5Gb / 12 hr /
    SE100 8.0 Gb / 7.2 hr 15.0 Gb / 8 hr 25.0 Gb/ 9.2 hr 50.0 Gb / 16 hr /
    PE75
    /
    75.0 Gb / 23 hr 150 Gb / 26 hr
    PE100
    /
    100.0 Gb / 30 hr 200 Gb / 33 hr
    PE150 24.0 Gb / 20 hr 45.0 Gb / 24 hr 75.0 Gb/ 25 hr 150.0 Gb / 42 hr 300 Gb / 45 hr

    *The sequencing time is for dual index (8+8);
    *The data throughput mentioned above is for a single chip; Salus Pro can run two chips simultaneously;
    * The time mentioned above is the theoretical sequencing time for a single chip;
    *The 1000 M chip is expected to be shipped in the Q4 of 2024

    Sequencing Methods Key
    Applications
    Data Volume
    Per Sample
    Read Length 80 M
    Samples / Run
    150 M
    Samples / Run
    250 M
    Samples / Run
    500 M
    Samples / Run
    1000 M
    Samples / Run
    Low-pass
    Whole Genome Sequencing
    NIPT 5 M reads SE 50 16 / 32 30 / 60 50 / 100 100 / 200 -
    CNV-seq / PGT-A 5 M reads SE 75 16 / 32 30 / 60 50 / 100 100 / 200 -
    Small
    Whole Genome Sequencing
    Shotgun Metagenomics 20 M reads SE 75 4 / 8 8 / 16 12 / 25 25 / 50 -
    Microbe, Virus WGS 1 Gb PE 150 24 / 48 45 / 90 75 / 150 150 / 300 300 / 600
    Targeted Sequencing
    (Target Enrichment / Amplicon Sequencing)
    Pathogen Targeted NGS (tNGS) 1 M reads SE 50 80 / 160 150 / 300 250 / 500 500 / 1000 -
    Small Panel Sequencing 1 Gb PE 150 24 / 48 45 / 90 75 / 150 150 / 300 300 / 600
    Large Panel Sequencing 10 Gb PE 150 3 / 6 5 / 10 7 / 15 15 / 30 30 / 60
    WES 12 Gb PE 150 2 / 4 3 / 7 6 / 12 12 / 25 25 / 50
    Methylation Sequencing Multi-cancer Early Detection 4 Gb PE 150 6 / 12 9 / 21 18 / 36 36 / 75 72 / 150
    RNA Sequencing Bulk RNA-seq 6 Gb PE 100 2 / 5 5 / 10 8 / 16 16 / 32 32 / 64
    Single Cell RNA Sequencing 20 - 50k reads/cell
    (Capture 10000 cells)
    PE 50 + 100 - - - 1 / 5 2 / 10
    Whole Genome Sequencing Human
    Whole Genome Sequencing (30X)
    100 Gb PE 150 - - - 1 / 3 2 / 6

    *Salus Pro can run two chips simultaneously;
    *The number of samples is estimated after careful consideration of library pooling bias and is for reference only

    Products Product Code
    Salus Pro Sequencer SL-Y00102
    Salus Pro Sequencing Reagent Set (SRM-SE50-80M) SL-S00101
    Salus Pro Sequencing Reagent Set (SRM-SE75-80M) SL-S00120
    Salus Pro Sequencing Reagent Set (PRM-PE75-150M) SL-S00122
    Salus Pro Sequencing Reagent Set (PRM-PE150-500M) SL-S00161
    Salus Pro Sequencing Reagent Set (PRM-PE150-1000M) SL-S00306
    *For more proeuct information and specifications please contact us

    Parameter Specifications
    Size 1265mm(W) x 700mm(D) x 675mm(H)
    Weight 210 Kg
    Power Input Voltage 100V - 240V~
    Frequency 50 / 60Hz
    Power 1200VA
    Fuse T15AH250V
    Instrument Configuration Type Capacitive
    Display 21.5 inch
    Resolution 1920x1080
    Operating Environment Temperature 19℃-25℃
    Humidity 20%RH-80%RH (No Condensation)
    Altitude ≤2000m
    Instrument Control Computer CPU Intel Xeon® Silver 4216
    Storage 32 GB DDR4+4
    Memory 10 TB HDD*4; 512 GB+2048 GB SSD
    OS Windows 10 x64
    Maximum sound pressure 75 dB(A)

  • Reads / Run (Up to two chips per run)
    1500 M / 2500 M
    Data Output / Run
    75 Gb ~ 1.5 Tb
    Run Time
    8 hr ~ 24 hr
    Application
    WES, WGS, Single Cell Sequencning and Spatial Transcriptomics, etc.
    • Highlighted Features
    • Specifications
    • Applications
    • Ordering Information
    • Instrument Specifications

    Sequencing Reagent Set Lanes Read Length 1 x Data / Run 2 x Data / Run Time Q30
    1500 M 4 SE 50 75 Gb 150 Gb 8 hr ≥ 90%
    PE 100 300 Gb 600 Gb 15 hr ≥ 85%
    PE 150 450 Gb 900 Gb 21 hr ≥ 85%
    3000 M* 4 PE 100 500 Gb 1000 Gb 17 hr ≥ 85%
    PE 150 750 Gb 1500 Gb 24 hr ≥ 85%

    *The sequencing time is dual index (8+8);
    *The data throughput mentioned above is for a single chip; Salus EVO can run two chips simultaneously;
    * The time mentioned above is the theoretical sequencing time for a single chip;
    *The 2500 M chip is expected to be shipped in the Q4 of 2024

    Sequencing Methods Applications Read Length 1 x 1500 M
    (Sample Size / Run)
    2 x 1500 M
    (Sample Size / Run)
    1 x 2500 M
    (Sample Size / Run)
    1500 M + 2500 M
    (Sample Size / Run)
    2 x 2500 M
    (Sample Size / Run)
    Targeted Sequencing
    (Capture / MultiplexPCR)
    (WES)
    (15 Gb / Sample)
    PE 150 30 60 50 80 100
    Solid Tumor Panel
    (35 Gb / Sample)
    PE 150 12 24 22 34 44

    Whole Genome Sequencing

    WGS
    (100 Gb / Sample)
    PE 150 5 10 8 13 16

    Methylation sequencing

    WGS
    (100 Gb / Sample)
    PE 150 5 10 8 13 16

    Transcriptomics Sequencing

    Single-cell Sequencing
    20 - 50K reads / Cell(~10000 Cells)
    PE 50 + 150 3 ~ 7 6 ~ 15 5 ~ 12 8 ~ 20 10 ~ 25
    Spatial Transcriptomics
    (200 Gb / Samples)
    PE 100 2 4 3 5 6

    *Salus EVO can run two chips simultaneously;
    *The number of samples is estimated after careful consideration of library pooling bias and is for reference only
    Products Product Code
    Salus EVO Sequencing Reagent Set(SRH-SE50-1500M) SL-S00357
    Salus EVO Sequencing Reagent Set(PRH-PE100-1500M) SL-S00360
    Salus EVO Sequencing Reagent Set(PRH-PE150-1500M) SL-S00361
    Salus EVO Sequencing Reagent Set(PRH-PE100-2500M) SL-S00365
    Salus EVO Sequencing Reagent Set(PRH-PE150-2500M) SL-S00366
    *For more proeuct information and specifications please contact us

    Parameter Specifications
    Dimensions 870 mm(W) × 995 mm(D) × 1616 mm(H)
    Weight 350 Kg
    Power Requirements Input voltage 200 V - 240 V~
    Frequency 50 / 60 Hz
    Power 1200 VA
    Fuse T15AH250V
    Instrument Configuration Type Capacitive
    Display 21.5 inch
    Resolution 1920 x 1080
    Operating Environment Temperature 19°C - 25°C
    Humidity 20% RH - 80% RH (No Condensation)
    Altitude ≤ 2000m
    Instrument Control Computer CPU 2 x AMD7643 (Single 48 core / 96 - thread 2.3 - 3.6G / 225W)
    Memory 1 TB GB DDR4
    Storage 11 TB HDD * 3 ; 512 GB + 3.84 TB * 2 SSD
    OS Windows 10 X64
    Maximum Sound Pressure 75 dB(A)

Click the product to learn more
Popular Products
    Contact Us

    info@salus-bio.com

    +86 0755-23745832

    20/F, BLK1, Hengtaiyu Research Park, Shenzhen, Guangdong, P.R. China